Your basket is currently empty!
Written by
According to Ideal boiler manufacturers, the L1 boiler fault code refers to a low water flow or high hot water flow temperature.
Your boiler’s flow pipe is where hot water leaves the boiler to heat your central heating system. This pipe will be hotter and show the Ideal boiler fault code “L1”.
Ideal Logic boilers have thermistors at the flow and return pipes. These sensors determine resistance based upon water temperature. The printed circuit board (PCB) transmits the resistance reading.
If the temperature stays within its operating range, the boiler will continue to work. If the temperature goes beyond or below its operating range, the fault code L1 Ideal boiler will indicate.
Book a boiler service >Start Your Project Today
Compare the Best Boilers & Offers Online Now
Get the best quotes for boiler installation online in under 1 minute now
The Ideal boiler should display a boiler fault code, then lock out. The boiler will stop working when it is locked out. This usually makes it safe.
Your boiler’s protection is assured by the ideal boiler fault codes. It is best to turn off your boiler if it shows fault codes but does not lockout.
In case of damage, the lock out protects the boiler’s components. It acts as a safety device, and will also stop the boiler from running.
As we have already mentioned, the safety lockout mode function was created as a safety measure. You shouldn’t reset your boiler until the problem is resolved.
Boilers should only be repaired by a Gas Safe engineer.
Your boiler engineer will need to look for the obvious signs that indicate if the L1 fault code has been displayed.
This could be the root of your problem.
The readings that your Ideal boiler’s flow thermistor is sending to your PCB might be inaccurate if it’s not working properly. This could lead to a temperature reading that is much higher than it really is.
This is recognized by the boiler’s PPB and locks it out. The PCB will give the Ideal boiler fault codes related to the problem. In this instance, L1
This is usually an old-age problem. The boiler’s vibrations could have caused the connections to be damaged or loosened by the boiler, causing intermittent readings to appear on the PCB.
This is one of the cheapest repairs for boilers. The cost of the thermistor will be around PS40-50. To diagnose and repair the problem, you should budget to pay around PS40-50.
Repairs will cost between PS120 and 150. A boiler engineer estimates that the repair will take approximately an hour.
The water they hold helps central heating systems maintain their pressure. The water comes directly from the mains and isn’t treated.
Some minerals can be found in mains water, while others may be more numerous. These minerals can settle on central heating systems.
Limescale settles most on the heat exchanger, but also on the flow tube.
The water that is contaminated by limescale tends to heat up a bit faster than the water in other parts of the heating system.
It is not dangerous but it can be dangerous. The flow thermistor monitors water flow’s temperature. If limescale settles near to the temperature sensor it will read a temperature higher than it should.
Your thermistor’s temperature reading may be too high due to limescale. However, the rest of the temperature might be right.
The problem is that the PCB cannot read the thermometer’s temperature. It won’t recognize the water temperature.
Manufacturers like Sentinel and Fernox make limescale removers. These are sometimes called heating silencing agents. This is a fluid you add to your central heating system. They break down limescale when they come in contact with it, allowing your water to flow more freely.
It can be caught in a limescale remover (a small filtration device), or flush the system to eliminate all limescale. You can also install a magnetic boiler filter.
If this doesn’t resolve the problem, the pipework or the thermistor may need to be replaced.
The heating pump circulates water around your heating system. This component should be checked if water circulation is disrupted.
It can be linked to an overheat. If the water is not circulated rapidly enough, or at all, the boiler will heat too fast.
First, a Gas Safe engineer will check that the pump has been set correctly. Grundfos UPS2 pumps are more recent than the UPS1. They have three speeds. If you have a lot of radiators, the fastest flow setting is required.
A technician will also inspect the pump to ensure it isn’t blocked. First, the engineer will bleed the pump using the bleed screw. Pumps with air locks can limit circulation.
They will also remove the boiler casing and take apart the pump to clean it. This is caused by heating sludge that builds up in your heating system.
If the shaft and bearings are in good condition, the pump can be re-fitted to remove the L1 fault code from the Ideal boiler.
This debris is likely to have come from rust. This causes the copper pipe to burst and copper pipes to burst.
This is the fastest and most effective method to avoid it.
If the boiler engineer is still unable to find the problem, it could be related to the PCB.
The PCB is the core of your boiler. If your boiler isn’t functioning properly, it won’t work correctly.
It must read the readings from the thermistor. If it doesn’t translate the readings correctly, it may lock the boiler.
They will first conduct a visual inspection. They will be looking for any loose wiring or burned out connections. They will need to fix any loose wiring or burned out connections.
If the visual inspection fails, they will need to test it with a multimeter. This will let you know if the PCB has failed.
If your boiler’s PCB is damaged, you will need to replace it. Depending on the model of boiler you have, a new PCB can cost between £400 to £500.
It may be time for you to look at the age of your boiler if it has begun showing L fault codes. Boilers that are older can be more expensive to repair and have a higher energy and gas bill. If your boiler is older than 10 years, an Ideal fault code or other issues with the boiler could indicate more problems.
Talk to a qualified engineer during your annual service. They may be able to give you an accurate assessment of the condition of your boiler. Get a quote online in less than 20 seconds if your error code is more catastrophoc than L1.
Written by
Start Your Project Today
Compare the Best Boilers & Offers Online Now
Get the best quotes for boiler installation online in under 1 minute now