The F5 Viessmann fault code can send alarm bells ringing however, if your Viessmann boiler is displaying an F5 fault code, don’t worry too much.
Fault codes can be a common occurrence in boilers as they age. Our article aims to provide answers to any questions you may have about your Viessmann boiler problems, as well as a step-by-step guide on how to fix it.
Old boiler? Compare the latest boiler quotes online now
Start Your Project Today
Compare the Best Boilers & Offers Online Now
Get the best quotes for boiler installation online in under 1 minute now
The F5 fault code on a Viessmann boiler indicates a faulty air pressure switch, which is responsible for measuring the gas pressure entering the boiler and sending readings to the PCB. If the switch sends a signal to the PCB indicating high or low gas pressure, the system will be locked out to prevent unsafe operation.
Older Viessmann manuals may also list a sticking mixture damper as a potential cause for the Viessmann F5 code, but this part is no longer included in Viessmann’s range.
The mixture damper is a small metal flap that seals the outlet of the fan, which is a crucial component of the boiler’s safe functioning. If the fan fails to start, the PCB will prevent further heating stages from taking place.
Nneed a new boiler? See the latest Viessmann boiler prices in our guide
The Viessmann F5 fault code can be caused by several factors. One possible cause is a problem with flow of gas into the boiler from the mains supply into the home. This therefore can prevent the gas pressure switch from registering sufficient levels within the boiler. The gas meter regulator is a common source of such problems, as it can become frozen in cold weather and prevent gas from flowing.
Another potential cause is a faulty gas valve, which can become stuck in the closed position and prevent gas from flowing into the unit. If the gas pressure switch itself is faulty, it may not be able to measure the gas pressure within the boiler, which can cause the PCB to prevent further gas from flowing into the unit.
In older models that feature a mixture damper, the F5 fault code can also result from a jammed damper. The rubber seal connecting the flap to the outlet can start to stick as it gets older over time, This will then cause further issues such as stopping the fan pressure from building up and opening it.
Finally, issues with the PCB can also cause the F5 fault code, as it is needed to control each electrical process within the boiler.
Over time wiring, connections and joinings can become loose therefore damage can be caused by moisture from leaks within the unit. In some cases, the faulty PCB may have ceased to function entirely, or may be displaying an inaccurate fault code as it fails.
No, as this is related to the gas supply, it is a legal requirement for a licensed Gas Safe engineer to carry out the diagnosis and repair.
It’s not recommended to attempt a DIY fix for this issue as it requires working inside the unit and may disrupt the gas supply. Remember, there is a mixture of gas water and electricity all in one place.
We obviously strongly advise you not to attempt to fix a Viessmann boiler unless trained, however, here is the potential process for an engineer to fix the Viessmann F5 issue.
Note: Always ensure that any modifications suggested by the engineer don’t affect your Viessmann boiler warranty or another cover with Viessmann.
The likelihood of needing a new Viessmann boiler is low with the F5 error code if caught early, however, if your boiler is older, say around 10 years old it may be time to consider a new one.
The price of repairs is usually around £250 on average, so it may be viable to repair your boiler once, but after this, if you consider the latest boiler prices, it may be cheaper in the long run to invest in a new Viessmann boiler.